Solis Alarm Codes FAQs

What is an AFCI Check FAULT Alarm?

An AFCI check FAULT alarm, as per the name indicates the presence of a fault and that your inverter requires a restart. It could also indicate that the inverter may need to be replaced.

What does a blank screen on a Solis Inverter indicate?

A blank screen on your Solis inverter can mean that the DC input voltage is low or missing, the DC string polarity is reversed, or a shorted Internal DC.

What does it mean when a Solis Inverter is stuck in the Initialising mode?

A Solis inverter stuck in its initialising mode can mean that it hasn’t yet received a signal from its DSP board or could have a malfunctioning internal power board.

What is a OV-G-V: Over-Grid-Voltage Alarm?

This alarm/error code indicates that your Solis Inverter has detected an excessively high grid voltage.

What is a UN-G-V: Under-Grid-Voltage Alarm?

The UN-G-V: Under-Grid-Voltage alarm/error code indicates that your Solis Inverter has detected an excessively low grid voltage.

What is an OV-G-F: Over-Grid-Frequency Alarm?

An OV-G-F: Over-Grid-Frequency Alarm indicates that your Solis inverter has detected an excessively high grid frequency.

What does a UN-G-F: Under-Grid-Frequency Alarm indicate?

An UN-G-F: Under-Grid-Frequency Alarm indicates that your Solis inverter has detected an excessively low grid frequency.

What is a NO-Grid Alarm?

A NO-Grid Alarm means that your Solis inverter has not detected any voltage from the grid.

What is an OV-DC: DC voltage is too high Alarm code?

An OV-DC: DC code means that your Solis inverter has detected a high direct current voltage.

What is an OV-BUS: DC bus voltage is too high alarm code?

This error code means that your Solis inverter has detected a high
DC voltage on the internal bus

What does the UN-BUS: DC bus voltage is too low alarm code mean?

If you see a UN-BUS: DC bus voltage is too low alarm code on your Solis inverter, it has detected an excessively low DC voltage on the internal bus.

What is an ILeak-PRO 01/02/03/04: Current leakage to ground alarm code?

An ILeak-PRO 01/02/03/04: Current leakage to ground alarm code means that the DC or AC Circuit has a current leakage.

What is a Fan-Fail alarm code?

When any of the fans of your Solis inverter stop working, your inverter will display a Fan-Fail alarm code.

What is a GRID-INTF: unstable grid or faulty power board alarm?

With a GRID-INTF: unstable grid or faulty power board alarm, your Solis inverter has detected an internal fault or grid instability.

What is an DC-INTF: DC Interference Fault alarm code?

As per the name, this alarm code indicates interference with direct currents as well as issues with internal components.

What is a G-IMP alarm code?

A G-IMP alarm code indicates high grid impedance.

What is an INI-FAULT: Initialization /rotection alarm code?

An INI-FAULT: Initialization/Protection alarm code shows that there are differing values between the Master and Slave DSP.

What is an PV ISO-PRO 01/02: Ground-fault detected on the DC side alarm code?

A PV ISO-PRO 01/02: Ground-fault detected on the DC side code means that your Solis Inverter has detected low DC insulation resistance. It can also indicate ground faults on one of the PV strings.

What is an ARC-Fault: An arc fault has been detected alarm code?

This alarm code indicates that your Solis Inverter detects an arc in the DC circuit.

What is an IG-AD: Grid current sampling failure alarm code?

This alarm code indicates an internal component failure.

What is an LimByVg: Power curtailed due to grid voltage alarm code?

As per the name, this code shows that power is being curtailed because of the grid voltage being too high or too low.

What is a LimbyTemp alarm code?

This alarm code means that the temperature is below 17C, alongside your inverter limiting its power to half.

What is a Relay-Fault alarm code?

As per the name, this alarm code means that there is a fault within the relay.

What is a DCinj-Fault alarm code?

A DCinj-Fault alarm code indicates that there is a high DC injection current.

What is a IGFOL-F alarm code?

This alarm code indicates a Grid Current Tracking Error.